2 Way Solenoid Valve

Vacuum Solenoid Valves

Vacuum Solenoid Valves

Product Specifications:

Body MaterialForged Brass and PP
BrandTork
Temperature of The Sucked FluidFrom -5 to +60 deg C
Working PressureFrom 0.5 to 3000 mbar abs
Max Absorption8 / 16.5 V.A. with AC and 6.5 /16 W with DC
ProtectionIP 65 for inserted connector

 

Product Description:
GENERAL FEATURES

• Wide pressure range, flow rate and orifis options.

• Solenoid valves are used with filters.

• Solenoid valves can be mounted in any positionwithout affecting its operation.

• Coil to be used in a vertical position.

ELECTRICAL CHARACTERISTICS

  • Continuous Duty : ED %100Coil
  • Insulation Class : H (180°C)(IEC 85)
  • Coil Impregnation : Polyester Fiber
  • GlassAmbient Temperature : -10°C, +60°C
  • Protection Degree : IP65 (ISO 60529)
  • On request; IP68Electric Plug
  • Connection : DIN 46340 3-Poles
  • Connector (DIN 43650)Connector
  • Specification : ISO 4400 / EN 175301-803 Form A,Spade Plug (Cable Ø6-8 mm)
  • Electrical Safety : IEC 335
  • Standard Voltages : AC 12V 15VA, 24V 15VA, 48V 15VA,230V 15VA, 230V 24VADC 12V 18W, 24V 18W, 48V 18W, 110V 18W On request other voltages
  • Voltages Tolerance : AC -15%, +10% DC -5%, +10%
  • Frequency : 50 Hz (60 Hz…)On request; Connector with LED, PWM Socket Specifycoil voltage with order

S1018 ( TORK-GY.3W) 3/2 Way Genaral Purpose Solenoid Valve

3/2 Way Genaral Purpose Solenoid Valve

Product Specifications:

Size1/8″-1/4″ BSP (on request NPT)
BrandTork
Pressure0 bar-16bar (on request 2.5 mm,2.5 mm orifice)
SeriesS1018 Series (G1/8″,G1/4″)
ApplicationAir,Water,Gas
Coil Voltage48 V, 110 V, 24 V, 110 V. 48 V, 12 V DC, 12 V AC, 230 V
Frequency50 Hz (60 Hz)
Continuous DutyED %100
Coil Insulation ClassH (180 deg C)(IEC 85)
Electric Plug ConnectionDIN 46340 3-Poles Connector(DIN43650)
PositionNormally Closed
Temperature-10 deg C-160 deg C

Product Description:
Specifications:

Valve Type / Order No
Connection Size
Orifice Size (mm)
Pressure (bar)
KV lt/ min
Fluid Temperature°C
Seal
Weight (kg)
MinMaxMinMax
N.CN.O
Diversion Systems
S1018.00.0181/8″1,8047161,5-10160VITON0,44
S1018.00.0251/8″2,5034123-10160VITON0,44
S1018.00.0351/8″3,5012105-10160VITON0,44
S1018.01.0181/4″1,8047161,5-10160VITON0,43
S1018.01.0251/4″2,5034123-10160VITON0,43
S1018.01.0351/4″3,5012105-10160VITON0,43

 

Tork S1018 3/2 Way Solenoid Valve

3/2 Way Genaral Purpose Solenoid Valve

Product Specifications:

Pressure0,5 bar – 16 bar (0 – 16bar – 1/8″-1/4″)
Size1/8″ -1/4″
BrandTork
MaterialTube-Stainless steel,Body-Brass,Seal-NBR,on request EPDM
MediaAir, Water, Gas, Fuel
SeriesS1018
Frequency50 Hz (60 Hz)
Coil Voltage110 V,48 V,12 V AC,230 V,12 V DC,24 V
Voltages ToleranceAC -15%,+10% DC -5%,+10%
Response TimeOpening time-30 ms,Closing Time-30 ms
Continuous DutyED %100
Max Viscosity5 deg E (~37cST veya mm2 /s)
PositionNormally Closed
ApplicationAir,Water,Gas
Temperature-10 deg C-80 deg C

Product Description:
Features:

  • Wide pressure range, a flow rate and orifice options.
  • Solenoid valves are used with the filter.
  • Solenoid valves can be mounted in any position without affecting its operation.
  • Coil to be used in a vertical position.

Tork 2/2 Way S1010 General Purpose Solenoid Valves

Tork 2/2 Way S1010 General Purpose Solenoid Valves

Product Specifications:

BrandTork
Frequency50 Hz,other frequencies on request; (60 Hz)
Connector SpecificationISO 4400 / EN 175301-803,Form A,Spade plug (Cable dia. 6-8 mm)
Electrical SafetyIEC 335
Standard Voltages110V,230V,For AC 12V,For DC 12V,110 V,48V,24V
Voltage TolerancesFor AC -15%; +10%,For DC -5%; +10%
Electric Plug ConnectionDIN 46340 3-poles connectors (DIN 43650)
Ambient TemperatureFrom -10 deg C +60 deg C
Continuous DutyED %100
Coil Insulation ClassH (180 deg C)
Coil ImpregnationPolyester Fiber Glass
Coil Encapsulation MaterialFiber Glass Reinforced
Protection DegreeIP 65 (EN 60529) with coil duly fitted with the plug connector

Product Description:
Features:

  • Suitable for non-aggressive liquids (water, light oil (2E) et), gaseous fluids (air, inert gases etc.)
  • Not suitable for use with dangerous fluids listed in Group 1
  • Minimum operating pressure differential 0,5 bar
  • High reliability, quality and performance, long life, corrosion resistance
  • Wide pressure ratings, range of flow rate and orifice options
  • Ideal for the automatic control of media in a wide range of applications.
  • TORK solenoid valves satisfy relevant 97/23/EC, Pressure Equipment Directive (PED) and 2006/95/EEC Low Voltage Directive (LVD).
  • Coils interchangeable
  • Flow factor Kv of each valve is indicated, so that the flow Q can be calculated as a function of pressure
  • Solenoid valves must be used with filtered fluids.
  • Solenoid valve can be mounted in any position without affecting operation, vertical with coil upwards preferred.
  • Standard pipe connection is G (BSP) (ISO 228-1) and on request, other pipe connections are available (NPT (ANSI 1.20.3)).

0,5 Bar-40 Bar S5012 (TORK-GKA) Normally Open 2 Way Solenoid Valve

0,5 Bar-40 Bar S5012 (TORK-GKA) Normally Open 2 Way Solenoid Valve

Product Specifications:

BrandTork
MaterialTube and internal part-SS, Body-Brass, Seal-VITON
Pressure0,5 bar-40 bar
SeriesS5012 Series (G3/8″,G1/2″,G3/4″,G1″)
ApplicationAir,hot and oily air
Coil Voltage48V, 230V, 12 V DC, 24V, 12V AC, 110V
Protection ClassIP65 and Exproof models
PositionNormally Closed
Temperature-10 deg C-160 deg C
Size1/8”-1″ BSP (on request NPT)

Product Description:
Features:

  • Wide pressure range, flow rate and orifis options.
  • Solenoid valves are used with filters.
  • Solenoid valves can be mounted in any position
  • Without affecting its operation. coil to be used in a vertical position.

Specification:

Valve Type / Order No
Connection Size
Orifice Size (mm)
Pressure (bar)
KV lt/ min
Fluid Temperature
Seal
Weight (kg)
MinMaxMinMax
S5013.00.0101/8″101000,6-10160VITON0,37
S5013.00.0181/8″1,80501,6-10160VITON0,37
S5013.00.0251/8″2,50203,2-10160VITON0,37
S5013.01.0101/4″101000,6-10160VITON0,36
S5013.01.0181/4″1,80501,6-10160VITON0,36
S5013.01.0251/4″2,50203,2-10160VITON0,36
S5013.023/8″12,50,54048-10160PTFE+VITON0,68
S5013.031/2″14,50,54070-10160PTFE+VITON0,71
S5013.043/4″170,54085-10160PTFE+VITON0,79
S5013.051″170,54090-10160PTFE+VITON0,96

 

Tork Pinch Solenoid Valve

Tork Pinch Solenoid Valve

Product Specifications:

Frequency50 Hz,other frequencies on request,(60 Hz) On request; connector with LED
BrandTork
Connector SpecificationISO 4400 / EN 175301-803,Form A,Spade plug (Cable Dia. 6-8 mm )
Electric Plug ConnectionDIN 46340 3-poles connectors (DIN 43650)
Standard VoltagesFor AC 12V,24V,48V,110V,230V but Mini. power 18 W,For DC 12V,110 V but Mini. power20
Voltage TolerancesFor AC %-15,%+10,For DC %-5
Protection DegreeIP 65 (EN 60529) with coil duly fitted with the plug connector
Electrical SafetyIEC 335
Coil Encapsulation MaterialFiber Glass Reinforced
Type2/2 Way
Continuous DutyED %100
Coil Insulation ClassH (180 deg C)
Coil ImpregnationPolyester Fiber Glass
Ambient TemperatureFrom -10 deg C +60 deg C

Product Description:
Tork series S8510 (N.C ) and S8511 (N.O ) pinch solenoid valves are 2/2 way normally closed and normally open.

Features:

  • TORK series S8510 (N.C ) and S8511 (N.O ) pinch solenoid valves are 2/2 way normally closed and normally open
  • The tubing is the only material in contact with the fluid
  • Fluid not in contact with metal parts
  • Suitable for media without producing neither turbulent flows nor dead spaces.Liquids, water, agressive media etc.
  • High flow rate under the same conditions of internal diameter of different solenoid valves
  • Valves are suitable for soft silicone tubings or others similar as to elasticity and hardness (50 Shore A )
  • Tubing are not inculed in our supply
  • Compact and low weight valve enabling easy and quick installation
  • High reliability, quality and performance
  • Flow factor Kv of each valve is indicated, so that the flow Q can be calculated as a function of pressure
  • Solenoid valves must be used with filtered fluids.
  • Solenoid valve can be mounted in any position without affecting operation ; vertical with coil upwards preferred.
  • If the soft tubings are different from the ones indicated, it’s important that the tubing maximum wall thickness is the same as shown in the table.
  • In case the tubings is not placed in its seat the solenoid valve could operate incorrectly