Tork 2-Way, 3-Way & Vacuum Solenoid Valves

This page covers the Tork range of general purpose 2/2 and 3/2 way solenoid valves, a normally open 2-way series, vacuum solenoid valves and pinch solenoid valves. They provide electrical on/off or diverting control for air, water, gas and other media in automation, packaging and process lines.

  • General purpose 2/2 way S1010 and 3/2 way S1018 valves
  • Normally open 2-way S5012 series
  • Vacuum solenoid valves in forged brass and PP bodies
  • Pinch solenoid valve for fluids that must not touch the valve internals
  • IP65 coils with DIN 43650 connector, IP68 on request
Tork 2-Way, 3-Way & Vacuum Solenoid Valves

Application-first selection

Tell us the medium, range and conditions — we match the product type to the duty.

Multi-category sourcing

Instruments, valves, filters, pneumatics and pumps on one enquiry.

Quotation against your specs

Every quote references the parameters you sent, so comparisons are like-for-like.

Engineer-to-engineer support

Ask a technical question before you commit to a model.

Solenoid Valves

Range, specifications & options

Tork solenoid valves are available through Flotronics. Tell us the fluid, pressure, port size and coil voltage and we will help you choose between the series, confirm seal materials and prepare a quotation. Confirm specifications against the datasheet for your exact model before ordering.

Need a quote for 2 Way Solenoid Valve?

Send the model or your operating parameters — unsure of a value? Mark it unknown and we will help. Monday to Saturday, 10:00 AM – 5:30 PM.

Vacuum Solenoid Valves

Tork Vacuum Solenoid Valves

Product Specifications:

Body Material Forged Brass and PP
Brand Tork
Temperature of The Sucked Fluid From -5 to +60 deg C
Working Pressure From 0.5 to 3000 mbar abs
Max Absorption 8 / 16.5 V.A. with AC and 6.5 /16 W with DC
Protection IP 65 for inserted connector

GENERAL FEATURES

• Wide pressure range, flow rate and orifis options.

• Solenoid valves are used with filters.

• Solenoid valves can be mounted in any positionwithout affecting its operation.

• Coil to be used in a vertical position.

ELECTRICAL CHARACTERISTICS

  • Continuous Duty : ED %100Coil
  • Insulation Class : H (180°C)(IEC 85)
  • Coil Impregnation : Polyester Fiber
  • GlassAmbient Temperature : -10°C, +60°C
  • Protection Degree : IP65 (ISO 60529)
  • On request; IP68Electric Plug
  • Connection : DIN 46340 3-Poles
  • Connector (DIN 43650)Connector
  • Specification : ISO 4400 / EN 175301-803 Form A,Spade Plug (Cable Ø6-8 mm)
  • Electrical Safety : IEC 335
  • Standard Voltages : AC 12V 15VA, 24V 15VA, 48V 15VA,230V 15VA, 230V 24VADC 12V 18W, 24V 18W, 48V 18W, 110V 18W On request other voltages
  • Voltages Tolerance : AC -15%, +10% DC -5%, +10%
  • Frequency : 50 Hz (60 Hz…)On request; Connector with LED, PWM Socket Specifycoil voltage with order
3/2 Way Genaral Purpose Solenoid Valve

Tork S1018 3/2 Way General Purpose Solenoid Valve

Product Specifications:

Size 1/8"-1/4" BSP (on request NPT)
Brand Tork
Pressure 0 bar-16bar (on request 2.5 mm,2.5 mm orifice)
Series S1018 Series (G1/8",G1/4")
Application Air,Water,Gas
Coil Voltage 48 V, 110 V, 24 V, 110 V. 48 V, 12 V DC, 12 V AC, 230 V
Frequency 50 Hz (60 Hz)
Continuous Duty ED %100
Coil Insulation Class H (180 deg C)(IEC 85)
Electric Plug Connection DIN 46340 3-Poles Connector(DIN43650)
Position Normally Closed
Temperature -10 deg C-160 deg C

Specifications:

Valve Type / Order No Connection Size Orifice Size (mm) Pressure (bar) KV lt/ min Fluid Temperature°C Seal Weight (kg)
Min Max Min Max
- - - N.C N.O Diversion Systems - -
S1018.00.018 1/8" 1,8 0 4 7 16 1,5 -10 160 VITON 0,44
S1018.00.025 1/8" 2,5 0 3 4 12 3 -10 160 VITON 0,44
S1018.00.035 1/8" 3,5 0 1 2 10 5 -10 160 VITON 0,44
S1018.01.018 1/4" 1,8 0 4 7 16 1,5 -10 160 VITON 0,43
S1018.01.025 1/4" 2,5 0 3 4 12 3 -10 160 VITON 0,43
S1018.01.035 1/4" 3,5 0 1 2 10 5 -10 160 VITON 0,43
3/2 Way Genaral Purpose Solenoid Valve

S1018 3/2 Way Solenoid Valve Specifications

Product Specifications:

Pressure 0,5 bar - 16 bar (0 - 16bar - 1/8"-1/4")
Size 1/8" -1/4"
Brand Tork
Material Tube-Stainless steel,Body-Brass,Seal-NBR,on request EPDM
Media Air, Water, Gas, Fuel
Series S1018
Frequency 50 Hz (60 Hz)
Coil Voltage 110 V,48 V,12 V AC,230 V,12 V DC,24 V
Voltages Tolerance AC -15%,+10% DC -5%,+10%
Response Time Opening time-30 ms,Closing Time-30 ms
Continuous Duty ED %100
Max Viscosity 5 deg E (~37cST veya mm2 /s)
Position Normally Closed
Application Air,Water,Gas
Temperature -10 deg C-80 deg C

Product Description:
Features:

  • Wide pressure range, a flow rate and orifice options.
  • Solenoid valves are used with the filter.
  • Solenoid valves can be mounted in any position without affecting its operation.
  • Coil to be used in a vertical position.
Tork 2/2 Way S1010 General Purpose Solenoid Valves

Tork 2/2 Way S1010 General Purpose Solenoid Valves

Product Specifications:

Brand Tork
Frequency 50 Hz,other frequencies on request; (60 Hz)
Connector Specification ISO 4400 / EN 175301-803,Form A,Spade plug (Cable dia. 6-8 mm)
Electrical Safety IEC 335
Standard Voltages 110V,230V,For AC 12V,For DC 12V,110 V,48V,24V
Voltage Tolerances For AC -15%; +10%,For DC -5%; +10%
Electric Plug Connection DIN 46340 3-poles connectors (DIN 43650)
Ambient Temperature From -10 deg C +60 deg C
Continuous Duty ED %100
Coil Insulation Class H (180 deg C)
Coil Impregnation Polyester Fiber Glass
Coil Encapsulation Material Fiber Glass Reinforced
Protection Degree IP 65 (EN 60529) with coil duly fitted with the plug connector

Product Description:
Features:

  • Suitable for non-aggressive liquids (water, light oil (2E) et), gaseous fluids (air, inert gases etc.)
  • Not suitable for use with dangerous fluids listed in Group 1
  • Minimum operating pressure differential 0,5 bar
  • High reliability, quality and performance, long life, corrosion resistance
  • Wide pressure ratings, range of flow rate and orifice options
  • Ideal for the automatic control of media in a wide range of applications.
  • TORK solenoid valves satisfy relevant 97/23/EC, Pressure Equipment Directive (PED) and 2006/95/EEC Low Voltage Directive (LVD).
  • Coils interchangeable
  • Flow factor Kv of each valve is indicated, so that the flow Q can be calculated as a function of pressure
  • Solenoid valves must be used with filtered fluids.
  • Solenoid valve can be mounted in any position without affecting operation, vertical with coil upwards preferred.
  • Standard pipe connection is G (BSP) (ISO 228-1) and on request, other pipe connections are available (NPT (ANSI 1.20.3)).
0,5 Bar-40 Bar S5012 (TORK-GKA) Normally Open 2 Way Solenoid Valve

0,5 Bar-40 Bar S5012 (TORK-GKA) Normally Open 2 Way Solenoid Valve

Product Specifications:

Brand Tork
Material Tube and internal part-SS, Body-Brass, Seal-VITON
Pressure 0,5 bar-40 bar
Series S5012 Series (G3/8",G1/2",G3/4",G1")
Application Air,hot and oily air
Coil Voltage 48V, 230V, 12 V DC, 24V, 12V AC, 110V
Protection Class IP65 and Exproof models
Position Normally Closed
Temperature -10 deg C-160 deg C
Size 1/8''-1" BSP (on request NPT)

Product Description:
Features:

  • Wide pressure range, flow rate and orifis options.
  • Solenoid valves are used with filters.
  • Solenoid valves can be mounted in any position
  • Without affecting its operation. coil to be used in a vertical position.

Specification:

Valve Type / Order No Connection Size Orifice Size (mm) Pressure (bar) KV lt/ min Fluid Temperature Seal Weight (kg)
Min Max Min Max
S5013.00.010 1/8" 1 0 100 0,6 -10 160 VITON 0,37
S5013.00.018 1/8" 1,8 0 50 1,6 -10 160 VITON 0,37
S5013.00.025 1/8" 2,5 0 20 3,2 -10 160 VITON 0,37
S5013.01.010 1/4" 1 0 100 0,6 -10 160 VITON 0,36
S5013.01.018 1/4" 1,8 0 50 1,6 -10 160 VITON 0,36
S5013.01.025 1/4" 2,5 0 20 3,2 -10 160 VITON 0,36
S5013.02 3/8" 12,5 0,5 40 48 -10 160 PTFE+VITON 0,68
S5013.03 1/2" 14,5 0,5 40 70 -10 160 PTFE+VITON 0,71
S5013.04 3/4" 17 0,5 40 85 -10 160 PTFE+VITON 0,79
S5013.05 1" 17 0,5 40 90 -10 160 PTFE+VITON 0,96
Tork Pinch Solenoid Valve

Tork Pinch Solenoid Valve

Product Specifications:

Frequency 50 Hz,other frequencies on request,(60 Hz) On request; connector with LED
Brand Tork
Connector Specification ISO 4400 / EN 175301-803,Form A,Spade plug (Cable Dia. 6-8 mm )
Electric Plug Connection DIN 46340 3-poles connectors (DIN 43650)
Standard Voltages For AC 12V,24V,48V,110V,230V but Mini. power 18 W,For DC 12V,110 V but Mini. power20
Voltage Tolerances For AC %-15,%+10,For DC %-5
Protection Degree IP 65 (EN 60529) with coil duly fitted with the plug connector
Electrical Safety IEC 335
Coil Encapsulation Material Fiber Glass Reinforced
Type 2/2 Way
Continuous Duty ED %100
Coil Insulation Class H (180 deg C)
Coil Impregnation Polyester Fiber Glass
Ambient Temperature From -10 deg C +60 deg C

Tork series S8510 (N.C ) and S8511 (N.O ) pinch solenoid valves are 2/2 way normally closed and normally open.

Features:

  • TORK series S8510 (N.C ) and S8511 (N.O ) pinch solenoid valves are 2/2 way normally closed and normally open
  • The tubing is the only material in contact with the fluid
  • Fluid not in contact with metal parts
  • Suitable for media without producing neither turbulent flows nor dead spaces.Liquids, water, agressive media etc.
  • High flow rate under the same conditions of internal diameter of different solenoid valves
  • Valves are suitable for soft silicone tubings or others similar as to elasticity and hardness (50 Shore A )
  • Tubing are not inculed in our supply
  • Compact and low weight valve enabling easy and quick installation
  • High reliability, quality and performance
  • Flow factor Kv of each valve is indicated, so that the flow Q can be calculated as a function of pressure
  • Solenoid valves must be used with filtered fluids.
  • Solenoid valve can be mounted in any position without affecting operation ; vertical with coil upwards preferred.
  • If the soft tubings are different from the ones indicated, it's important that the tubing maximum wall thickness is the same as shown in the table.
  • In case the tubings is not placed in its seat the solenoid valve could operate incorrectly

Selection guide

What to specify for an accurate quotation

These parameters decide which variant suits your duty. Send what you know — unknown values can be marked for engineering assistance.

Media and seal material
Tell us the fluid (steam, hot water, air, gas, oil) so body, core and seal materials such as PTFE, NBR, EPDM or FKM can be matched.
Operating pressure range
Solenoid valves operate within a defined differential pressure window; running outside it can cause failure to open or seat leakage.
Port size and thread
Connection size and thread type (BSP or NPT) must match your line and influence available flow.
Orifice size and flow (Kv)
Orifice and Kv decide how much flow the valve passes at your pressure drop, so size it to the duty rather than the pipe.
Coil voltage, frequency and duty
AC or DC supply, voltage and continuous-duty rating must match your control panel.
Valve function
Specify 2/2 or 3/2 way and normally closed or normally open, as this defines the fail-safe state of the line.
Temperature and enclosure
Fluid and ambient temperature, and the IP or hazardous-area rating, decide coil class and housing choice.

Typical applications

  • Pneumatic cylinder and actuator control
  • Water and gas line isolation
  • Vacuum handling and pick-and-place
  • Packaging and filling machines
  • Dosing and sampling lines

FAQ

Frequently asked questions

Answers to the questions buyers most often ask before requesting a quotation.

What is the difference between 2-way and 3-way solenoid valves?

A 2-way valve opens or closes a single flow path. A 3-way valve switches a port between two paths or exhausts a downstream line, which is common for single-acting cylinders and actuators. Tell us your circuit and we will suggest the right type.

When should I use a normally open solenoid valve?

Choose normally open when the line must stay flowing if power fails, and closed only when energised. Normally closed is the usual choice when the safe state is shut. Share your safety requirement and we will confirm.

Are solenoid valves suitable for dirty media?

Solenoid valves are generally used with a filter upstream, as the page notes. For viscous or particulate fluids a pinch type valve may suit better. Describe the fluid and we can advise.

Can I get a coil with a different voltage?

Several AC and DC voltages are listed, with others on request. Send your control voltage and frequency along with the model and we will confirm coil availability.

Need the right solenoid valve for your circuit?

Send us the media, size, pressure and temperature, connection and quantity for a quotation, or ask our engineers to help you select the right option.