2 Way Solenoid Valve

Vacuum Solenoid Valves

Vacuum Solenoid Valves

Product Specifications:

Body Material Forged Brass and PP
Brand Tork
Temperature of The Sucked Fluid From -5 to +60 deg C
Working Pressure From 0.5 to 3000 mbar abs
Max Absorption 8 / 16.5 V.A. with AC and 6.5 /16 W with DC
Protection IP 65 for inserted connector

 

Product Description:
GENERAL FEATURES

• Wide pressure range, flow rate and orifis options.

• Solenoid valves are used with filters.

• Solenoid valves can be mounted in any positionwithout affecting its operation.

• Coil to be used in a vertical position.

ELECTRICAL CHARACTERISTICS

  • Continuous Duty : ED %100Coil
  • Insulation Class : H (180°C)(IEC 85)
  • Coil Impregnation : Polyester Fiber
  • GlassAmbient Temperature : -10°C, +60°C
  • Protection Degree : IP65 (ISO 60529)
  • On request; IP68Electric Plug
  • Connection : DIN 46340 3-Poles
  • Connector (DIN 43650)Connector
  • Specification : ISO 4400 / EN 175301-803 Form A,Spade Plug (Cable Ø6-8 mm)
  • Electrical Safety : IEC 335
  • Standard Voltages : AC 12V 15VA, 24V 15VA, 48V 15VA,230V 15VA, 230V 24VADC 12V 18W, 24V 18W, 48V 18W, 110V 18W On request other voltages
  • Voltages Tolerance : AC -15%, +10% DC -5%, +10%
  • Frequency : 50 Hz (60 Hz…)On request; Connector with LED, PWM Socket Specifycoil voltage with order

S1018 ( TORK-GY.3W) 3/2 Way Genaral Purpose Solenoid Valve

3/2 Way Genaral Purpose Solenoid Valve

Product Specifications:

Size 1/8″-1/4″ BSP (on request NPT)
Brand Tork
Pressure 0 bar-16bar (on request 2.5 mm,2.5 mm orifice)
Series S1018 Series (G1/8″,G1/4″)
Application Air,Water,Gas
Coil Voltage 48 V, 110 V, 24 V, 110 V. 48 V, 12 V DC, 12 V AC, 230 V
Frequency 50 Hz (60 Hz)
Continuous Duty ED %100
Coil Insulation Class H (180 deg C)(IEC 85)
Electric Plug Connection DIN 46340 3-Poles Connector(DIN43650)
Position Normally Closed
Temperature -10 deg C-160 deg C

Product Description:
Specifications:

Valve Type / Order No
Connection Size
Orifice Size (mm)
Pressure (bar)
KV lt/ min
Fluid Temperature°C
Seal
Weight (kg)
Min Max Min Max
N.C N.O
Diversion Systems
S1018.00.018 1/8″ 1,8 0 4 7 16 1,5 -10 160 VITON 0,44
S1018.00.025 1/8″ 2,5 0 3 4 12 3 -10 160 VITON 0,44
S1018.00.035 1/8″ 3,5 0 1 2 10 5 -10 160 VITON 0,44
S1018.01.018 1/4″ 1,8 0 4 7 16 1,5 -10 160 VITON 0,43
S1018.01.025 1/4″ 2,5 0 3 4 12 3 -10 160 VITON 0,43
S1018.01.035 1/4″ 3,5 0 1 2 10 5 -10 160 VITON 0,43

 

Tork S1018 3/2 Way Solenoid Valve

3/2 Way Genaral Purpose Solenoid Valve

Product Specifications:

Pressure 0,5 bar – 16 bar (0 – 16bar – 1/8″-1/4″)
Size 1/8″ -1/4″
Brand Tork
Material Tube-Stainless steel,Body-Brass,Seal-NBR,on request EPDM
Media Air, Water, Gas, Fuel
Series S1018
Frequency 50 Hz (60 Hz)
Coil Voltage 110 V,48 V,12 V AC,230 V,12 V DC,24 V
Voltages Tolerance AC -15%,+10% DC -5%,+10%
Response Time Opening time-30 ms,Closing Time-30 ms
Continuous Duty ED %100
Max Viscosity 5 deg E (~37cST veya mm2 /s)
Position Normally Closed
Application Air,Water,Gas
Temperature -10 deg C-80 deg C

Product Description:
Features:

  • Wide pressure range, a flow rate and orifice options.
  • Solenoid valves are used with the filter.
  • Solenoid valves can be mounted in any position without affecting its operation.
  • Coil to be used in a vertical position.

Tork 2/2 Way S1010 General Purpose Solenoid Valves

Tork 2/2 Way S1010 General Purpose Solenoid Valves

Product Specifications:

Brand Tork
Frequency 50 Hz,other frequencies on request; (60 Hz)
Connector Specification ISO 4400 / EN 175301-803,Form A,Spade plug (Cable dia. 6-8 mm)
Electrical Safety IEC 335
Standard Voltages 110V,230V,For AC 12V,For DC 12V,110 V,48V,24V
Voltage Tolerances For AC -15%; +10%,For DC -5%; +10%
Electric Plug Connection DIN 46340 3-poles connectors (DIN 43650)
Ambient Temperature From -10 deg C +60 deg C
Continuous Duty ED %100
Coil Insulation Class H (180 deg C)
Coil Impregnation Polyester Fiber Glass
Coil Encapsulation Material Fiber Glass Reinforced
Protection Degree IP 65 (EN 60529) with coil duly fitted with the plug connector

Product Description:
Features:

  • Suitable for non-aggressive liquids (water, light oil (2E) et), gaseous fluids (air, inert gases etc.)
  • Not suitable for use with dangerous fluids listed in Group 1
  • Minimum operating pressure differential 0,5 bar
  • High reliability, quality and performance, long life, corrosion resistance
  • Wide pressure ratings, range of flow rate and orifice options
  • Ideal for the automatic control of media in a wide range of applications.
  • TORK solenoid valves satisfy relevant 97/23/EC, Pressure Equipment Directive (PED) and 2006/95/EEC Low Voltage Directive (LVD).
  • Coils interchangeable
  • Flow factor Kv of each valve is indicated, so that the flow Q can be calculated as a function of pressure
  • Solenoid valves must be used with filtered fluids.
  • Solenoid valve can be mounted in any position without affecting operation, vertical with coil upwards preferred.
  • Standard pipe connection is G (BSP) (ISO 228-1) and on request, other pipe connections are available (NPT (ANSI 1.20.3)).

0,5 Bar-40 Bar S5012 (TORK-GKA) Normally Open 2 Way Solenoid Valve

0,5 Bar-40 Bar S5012 (TORK-GKA) Normally Open 2 Way Solenoid Valve

Product Specifications:

Brand Tork
Material Tube and internal part-SS, Body-Brass, Seal-VITON
Pressure 0,5 bar-40 bar
Series S5012 Series (G3/8″,G1/2″,G3/4″,G1″)
Application Air,hot and oily air
Coil Voltage 48V, 230V, 12 V DC, 24V, 12V AC, 110V
Protection Class IP65 and Exproof models
Position Normally Closed
Temperature -10 deg C-160 deg C
Size 1/8”-1″ BSP (on request NPT)

Product Description:
Features:

  • Wide pressure range, flow rate and orifis options.
  • Solenoid valves are used with filters.
  • Solenoid valves can be mounted in any position
  • Without affecting its operation. coil to be used in a vertical position.

Specification:

Valve Type / Order No
Connection Size
Orifice Size (mm)
Pressure (bar)
KV lt/ min
Fluid Temperature
Seal
Weight (kg)
Min Max Min Max
S5013.00.010 1/8″ 1 0 100 0,6 -10 160 VITON 0,37
S5013.00.018 1/8″ 1,8 0 50 1,6 -10 160 VITON 0,37
S5013.00.025 1/8″ 2,5 0 20 3,2 -10 160 VITON 0,37
S5013.01.010 1/4″ 1 0 100 0,6 -10 160 VITON 0,36
S5013.01.018 1/4″ 1,8 0 50 1,6 -10 160 VITON 0,36
S5013.01.025 1/4″ 2,5 0 20 3,2 -10 160 VITON 0,36
S5013.02 3/8″ 12,5 0,5 40 48 -10 160 PTFE+VITON 0,68
S5013.03 1/2″ 14,5 0,5 40 70 -10 160 PTFE+VITON 0,71
S5013.04 3/4″ 17 0,5 40 85 -10 160 PTFE+VITON 0,79
S5013.05 1″ 17 0,5 40 90 -10 160 PTFE+VITON 0,96

 

Tork Pinch Solenoid Valve

Tork Pinch Solenoid Valve

Product Specifications:

Frequency 50 Hz,other frequencies on request,(60 Hz) On request; connector with LED
Brand Tork
Connector Specification ISO 4400 / EN 175301-803,Form A,Spade plug (Cable Dia. 6-8 mm )
Electric Plug Connection DIN 46340 3-poles connectors (DIN 43650)
Standard Voltages For AC 12V,24V,48V,110V,230V but Mini. power 18 W,For DC 12V,110 V but Mini. power20
Voltage Tolerances For AC %-15,%+10,For DC %-5
Protection Degree IP 65 (EN 60529) with coil duly fitted with the plug connector
Electrical Safety IEC 335
Coil Encapsulation Material Fiber Glass Reinforced
Type 2/2 Way
Continuous Duty ED %100
Coil Insulation Class H (180 deg C)
Coil Impregnation Polyester Fiber Glass
Ambient Temperature From -10 deg C +60 deg C

Product Description:
Tork series S8510 (N.C ) and S8511 (N.O ) pinch solenoid valves are 2/2 way normally closed and normally open.

Features:

  • TORK series S8510 (N.C ) and S8511 (N.O ) pinch solenoid valves are 2/2 way normally closed and normally open
  • The tubing is the only material in contact with the fluid
  • Fluid not in contact with metal parts
  • Suitable for media without producing neither turbulent flows nor dead spaces.Liquids, water, agressive media etc.
  • High flow rate under the same conditions of internal diameter of different solenoid valves
  • Valves are suitable for soft silicone tubings or others similar as to elasticity and hardness (50 Shore A )
  • Tubing are not inculed in our supply
  • Compact and low weight valve enabling easy and quick installation
  • High reliability, quality and performance
  • Flow factor Kv of each valve is indicated, so that the flow Q can be calculated as a function of pressure
  • Solenoid valves must be used with filtered fluids.
  • Solenoid valve can be mounted in any position without affecting operation ; vertical with coil upwards preferred.
  • If the soft tubings are different from the ones indicated, it’s important that the tubing maximum wall thickness is the same as shown in the table.
  • In case the tubings is not placed in its seat the solenoid valve could operate incorrectly