- Home
- Products
- Industrial Valves
- 2 Way Solenoid Valve
Solenoid Valves
Tork 2-Way, 3-Way & Vacuum Solenoid Valves
This page covers the Tork range of general purpose 2/2 and 3/2 way solenoid valves, a normally open 2-way series, vacuum solenoid valves and pinch solenoid valves. They provide electrical on/off or diverting control for air, water, gas and other media in automation, packaging and process lines.
- General purpose 2/2 way S1010 and 3/2 way S1018 valves
- Normally open 2-way S5012 series
- Vacuum solenoid valves in forged brass and PP bodies
- Pinch solenoid valve for fluids that must not touch the valve internals
- IP65 coils with DIN 43650 connector, IP68 on request

Application-first selection
Tell us the medium, range and conditions — we match the product type to the duty.
Multi-category sourcing
Instruments, valves, filters, pneumatics and pumps on one enquiry.
Quotation against your specs
Every quote references the parameters you sent, so comparisons are like-for-like.
Engineer-to-engineer support
Ask a technical question before you commit to a model.
Solenoid Valves
Range, specifications & options
Tork solenoid valves are available through Flotronics. Tell us the fluid, pressure, port size and coil voltage and we will help you choose between the series, confirm seal materials and prepare a quotation. Confirm specifications against the datasheet for your exact model before ordering.
Need a quote for 2 Way Solenoid Valve?
Send the model or your operating parameters — unsure of a value? Mark it unknown and we will help. Monday to Saturday, 10:00 AM – 5:30 PM.

Tork Vacuum Solenoid Valves
Product Specifications:
| Body Material | Forged Brass and PP |
| Brand | Tork |
| Temperature of The Sucked Fluid | From -5 to +60 deg C |
| Working Pressure | From 0.5 to 3000 mbar abs |
| Max Absorption | 8 / 16.5 V.A. with AC and 6.5 /16 W with DC |
| Protection | IP 65 for inserted connector |
GENERAL FEATURES
• Wide pressure range, flow rate and orifis options.
• Solenoid valves are used with filters.
• Solenoid valves can be mounted in any positionwithout affecting its operation.
• Coil to be used in a vertical position.
ELECTRICAL CHARACTERISTICS
- Continuous Duty : ED %100Coil
- Insulation Class : H (180°C)(IEC 85)
- Coil Impregnation : Polyester Fiber
- GlassAmbient Temperature : -10°C, +60°C
- Protection Degree : IP65 (ISO 60529)
- On request; IP68Electric Plug
- Connection : DIN 46340 3-Poles
- Connector (DIN 43650)Connector
- Specification : ISO 4400 / EN 175301-803 Form A,Spade Plug (Cable Ø6-8 mm)
- Electrical Safety : IEC 335
- Standard Voltages : AC 12V 15VA, 24V 15VA, 48V 15VA,230V 15VA, 230V 24VADC 12V 18W, 24V 18W, 48V 18W, 110V 18W On request other voltages
- Voltages Tolerance : AC -15%, +10% DC -5%, +10%
- Frequency : 50 Hz (60 Hz…)On request; Connector with LED, PWM Socket Specifycoil voltage with order

Tork S1018 3/2 Way General Purpose Solenoid Valve
Product Specifications:
| Size | 1/8"-1/4" BSP (on request NPT) |
| Brand | Tork |
| Pressure | 0 bar-16bar (on request 2.5 mm,2.5 mm orifice) |
| Series | S1018 Series (G1/8",G1/4") |
| Application | Air,Water,Gas |
| Coil Voltage | 48 V, 110 V, 24 V, 110 V. 48 V, 12 V DC, 12 V AC, 230 V |
| Frequency | 50 Hz (60 Hz) |
| Continuous Duty | ED %100 |
| Coil Insulation Class | H (180 deg C)(IEC 85) |
| Electric Plug Connection | DIN 46340 3-Poles Connector(DIN43650) |
| Position | Normally Closed |
| Temperature | -10 deg C-160 deg C |
Specifications:
| Valve Type / Order No | Connection Size | Orifice Size (mm) | Pressure (bar) | KV lt/ min | Fluid Temperature°C | Seal | Weight (kg) | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Min | Max | Min | Max | ||||||||
| - | - | - | N.C | N.O | Diversion Systems | - | - | ||||
| S1018.00.018 | 1/8" | 1,8 | 0 | 4 | 7 | 16 | 1,5 | -10 | 160 | VITON | 0,44 |
| S1018.00.025 | 1/8" | 2,5 | 0 | 3 | 4 | 12 | 3 | -10 | 160 | VITON | 0,44 |
| S1018.00.035 | 1/8" | 3,5 | 0 | 1 | 2 | 10 | 5 | -10 | 160 | VITON | 0,44 |
| S1018.01.018 | 1/4" | 1,8 | 0 | 4 | 7 | 16 | 1,5 | -10 | 160 | VITON | 0,43 |
| S1018.01.025 | 1/4" | 2,5 | 0 | 3 | 4 | 12 | 3 | -10 | 160 | VITON | 0,43 |
| S1018.01.035 | 1/4" | 3,5 | 0 | 1 | 2 | 10 | 5 | -10 | 160 | VITON | 0,43 |

S1018 3/2 Way Solenoid Valve Specifications
Product Specifications:
| Pressure | 0,5 bar - 16 bar (0 - 16bar - 1/8"-1/4") |
| Size | 1/8" -1/4" |
| Brand | Tork |
| Material | Tube-Stainless steel,Body-Brass,Seal-NBR,on request EPDM |
| Media | Air, Water, Gas, Fuel |
| Series | S1018 |
| Frequency | 50 Hz (60 Hz) |
| Coil Voltage | 110 V,48 V,12 V AC,230 V,12 V DC,24 V |
| Voltages Tolerance | AC -15%,+10% DC -5%,+10% |
| Response Time | Opening time-30 ms,Closing Time-30 ms |
| Continuous Duty | ED %100 |
| Max Viscosity | 5 deg E (~37cST veya mm2 /s) |
| Position | Normally Closed |
| Application | Air,Water,Gas |
| Temperature | -10 deg C-80 deg C |
Product Description:
Features:
- Wide pressure range, a flow rate and orifice options.
- Solenoid valves are used with the filter.
- Solenoid valves can be mounted in any position without affecting its operation.
- Coil to be used in a vertical position.

Tork 2/2 Way S1010 General Purpose Solenoid Valves
Product Specifications:
| Brand | Tork |
| Frequency | 50 Hz,other frequencies on request; (60 Hz) |
| Connector Specification | ISO 4400 / EN 175301-803,Form A,Spade plug (Cable dia. 6-8 mm) |
| Electrical Safety | IEC 335 |
| Standard Voltages | 110V,230V,For AC 12V,For DC 12V,110 V,48V,24V |
| Voltage Tolerances | For AC -15%; +10%,For DC -5%; +10% |
| Electric Plug Connection | DIN 46340 3-poles connectors (DIN 43650) |
| Ambient Temperature | From -10 deg C +60 deg C |
| Continuous Duty | ED %100 |
| Coil Insulation Class | H (180 deg C) |
| Coil Impregnation | Polyester Fiber Glass |
| Coil Encapsulation Material | Fiber Glass Reinforced |
| Protection Degree | IP 65 (EN 60529) with coil duly fitted with the plug connector |
Product Description:
Features:
- Suitable for non-aggressive liquids (water, light oil (2E) et), gaseous fluids (air, inert gases etc.)
- Not suitable for use with dangerous fluids listed in Group 1
- Minimum operating pressure differential 0,5 bar
- High reliability, quality and performance, long life, corrosion resistance
- Wide pressure ratings, range of flow rate and orifice options
- Ideal for the automatic control of media in a wide range of applications.
- TORK solenoid valves satisfy relevant 97/23/EC, Pressure Equipment Directive (PED) and 2006/95/EEC Low Voltage Directive (LVD).
- Coils interchangeable
- Flow factor Kv of each valve is indicated, so that the flow Q can be calculated as a function of pressure
- Solenoid valves must be used with filtered fluids.
- Solenoid valve can be mounted in any position without affecting operation, vertical with coil upwards preferred.
- Standard pipe connection is G (BSP) (ISO 228-1) and on request, other pipe connections are available (NPT (ANSI 1.20.3)).

0,5 Bar-40 Bar S5012 (TORK-GKA) Normally Open 2 Way Solenoid Valve
Product Specifications:
| Brand | Tork |
| Material | Tube and internal part-SS, Body-Brass, Seal-VITON |
| Pressure | 0,5 bar-40 bar |
| Series | S5012 Series (G3/8",G1/2",G3/4",G1") |
| Application | Air,hot and oily air |
| Coil Voltage | 48V, 230V, 12 V DC, 24V, 12V AC, 110V |
| Protection Class | IP65 and Exproof models |
| Position | Normally Closed |
| Temperature | -10 deg C-160 deg C |
| Size | 1/8''-1" BSP (on request NPT) |
Product Description:
Features:
- Wide pressure range, flow rate and orifis options.
- Solenoid valves are used with filters.
- Solenoid valves can be mounted in any position
- Without affecting its operation. coil to be used in a vertical position.
Specification:
| Valve Type / Order No | Connection Size | Orifice Size (mm) | Pressure (bar) | KV lt/ min | Fluid Temperature | Seal | Weight (kg) | ||
|---|---|---|---|---|---|---|---|---|---|
| Min | Max | Min | Max | ||||||
| S5013.00.010 | 1/8" | 1 | 0 | 100 | 0,6 | -10 | 160 | VITON | 0,37 |
| S5013.00.018 | 1/8" | 1,8 | 0 | 50 | 1,6 | -10 | 160 | VITON | 0,37 |
| S5013.00.025 | 1/8" | 2,5 | 0 | 20 | 3,2 | -10 | 160 | VITON | 0,37 |
| S5013.01.010 | 1/4" | 1 | 0 | 100 | 0,6 | -10 | 160 | VITON | 0,36 |
| S5013.01.018 | 1/4" | 1,8 | 0 | 50 | 1,6 | -10 | 160 | VITON | 0,36 |
| S5013.01.025 | 1/4" | 2,5 | 0 | 20 | 3,2 | -10 | 160 | VITON | 0,36 |
| S5013.02 | 3/8" | 12,5 | 0,5 | 40 | 48 | -10 | 160 | PTFE+VITON | 0,68 |
| S5013.03 | 1/2" | 14,5 | 0,5 | 40 | 70 | -10 | 160 | PTFE+VITON | 0,71 |
| S5013.04 | 3/4" | 17 | 0,5 | 40 | 85 | -10 | 160 | PTFE+VITON | 0,79 |
| S5013.05 | 1" | 17 | 0,5 | 40 | 90 | -10 | 160 | PTFE+VITON | 0,96 |

Tork Pinch Solenoid Valve
Product Specifications:
| Frequency | 50 Hz,other frequencies on request,(60 Hz) On request; connector with LED |
| Brand | Tork |
| Connector Specification | ISO 4400 / EN 175301-803,Form A,Spade plug (Cable Dia. 6-8 mm ) |
| Electric Plug Connection | DIN 46340 3-poles connectors (DIN 43650) |
| Standard Voltages | For AC 12V,24V,48V,110V,230V but Mini. power 18 W,For DC 12V,110 V but Mini. power20 |
| Voltage Tolerances | For AC %-15,%+10,For DC %-5 |
| Protection Degree | IP 65 (EN 60529) with coil duly fitted with the plug connector |
| Electrical Safety | IEC 335 |
| Coil Encapsulation Material | Fiber Glass Reinforced |
| Type | 2/2 Way |
| Continuous Duty | ED %100 |
| Coil Insulation Class | H (180 deg C) |
| Coil Impregnation | Polyester Fiber Glass |
| Ambient Temperature | From -10 deg C +60 deg C |
Tork series S8510 (N.C ) and S8511 (N.O ) pinch solenoid valves are 2/2 way normally closed and normally open.
Features:
- TORK series S8510 (N.C ) and S8511 (N.O ) pinch solenoid valves are 2/2 way normally closed and normally open
- The tubing is the only material in contact with the fluid
- Fluid not in contact with metal parts
- Suitable for media without producing neither turbulent flows nor dead spaces.Liquids, water, agressive media etc.
- High flow rate under the same conditions of internal diameter of different solenoid valves
- Valves are suitable for soft silicone tubings or others similar as to elasticity and hardness (50 Shore A )
- Tubing are not inculed in our supply
- Compact and low weight valve enabling easy and quick installation
- High reliability, quality and performance
- Flow factor Kv of each valve is indicated, so that the flow Q can be calculated as a function of pressure
- Solenoid valves must be used with filtered fluids.
- Solenoid valve can be mounted in any position without affecting operation ; vertical with coil upwards preferred.
- If the soft tubings are different from the ones indicated, it's important that the tubing maximum wall thickness is the same as shown in the table.
- In case the tubings is not placed in its seat the solenoid valve could operate incorrectly
Selection guide
What to specify for an accurate quotation
These parameters decide which variant suits your duty. Send what you know — unknown values can be marked for engineering assistance.
Typical applications
- Pneumatic cylinder and actuator control
- Water and gas line isolation
- Vacuum handling and pick-and-place
- Packaging and filling machines
- Dosing and sampling lines
FAQ
Frequently asked questions
Answers to the questions buyers most often ask before requesting a quotation.
What is the difference between 2-way and 3-way solenoid valves?
A 2-way valve opens or closes a single flow path. A 3-way valve switches a port between two paths or exhausts a downstream line, which is common for single-acting cylinders and actuators. Tell us your circuit and we will suggest the right type.
When should I use a normally open solenoid valve?
Choose normally open when the line must stay flowing if power fails, and closed only when energised. Normally closed is the usual choice when the safe state is shut. Share your safety requirement and we will confirm.
Are solenoid valves suitable for dirty media?
Solenoid valves are generally used with a filter upstream, as the page notes. For viscous or particulate fluids a pinch type valve may suit better. Describe the fluid and we can advise.
Can I get a coil with a different voltage?
Several AC and DC voltages are listed, with others on request. Send your control voltage and frequency along with the model and we will confirm coil availability.
Related
Related products & guides
Need the right solenoid valve for your circuit?
Send us the media, size, pressure and temperature, connection and quantity for a quotation, or ask our engineers to help you select the right option.