Skip to content
Industrial instrumentation, valves, filtration, pneumatics & pumps — Chennai
Request a Quote

Filter Elements

Compressed Air Filter Elements: Pre, Fine, Micro & Carbon Grades

Filter elements are the replaceable part of a compressed air filter housing, and the grade you choose sets how much oil and particulate reach your equipment.

  • Grades PF, AO, AF, AE, FF, AT, AAT
  • Sodium borosilicate fibre glass material
  • Model FE100
  • Performance tested to ISO 12500 methods as stated
  • Minimum order quantity stated on page
  • Carbon filter elements
Compressed Air Filter Elements: Pre, Fine, Micro & Carbon Grades

Application-first selection

Tell us the medium, range and conditions — we match the product type to the duty.

Multi-category sourcing

Instruments, valves, filters, pneumatics and pumps on one enquiry.

Quotation against your specs

Every quote references the parameters you sent, so comparisons are like-for-like.

Engineer-to-engineer support

Ask a technical question before you commit to a model.

Filter Elements

Range, specifications & options

The FE100 elements are made of sodium borosilicate fibre glass in seven grades, PF, AO, AF, AE, FF, AT and AAT, covering primary filtration through ultra-fine and oil vapour grades. The page also references ISO 12500 test methods. Send us your housing make, element size and required grade and we will confirm and quote. Confirm specifications against the datasheet for your exact model before ordering.

Need a quote for Filter Elements?

Send the model or your operating parameters — unsure of a value? Mark it unknown and we will help. Monday to Saturday, 10:00 AM – 5:30 PM.

Product Details:

Model FE100
Filter element grade PF/AO/AF/AE/FF/AT/AAT
Color White
MOQ 20pcs
Brand Flotronics
  • Material: Sodium Borosilicate Fiber Glass

Flotronics filter element with 7 Grades: PF/AO/AF/AE/FF/AT/AAT

Description:

PF As a primary filter, particles whose diameter more than 5μm can be remove,the maxi. residual oil content is negligible
AO High efficiency general protection, dust particles, water mist & oil mist whose diameter more than 1 μm can be removed, the residual content of oil mist does not exceed 0.6mg/m³(21???1ppm(w).
AF High efficiency oil remove filtration, dust particles, water mist and oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.01mg/m³(21 °C),0.01ppm(w)
AE Ultra-efficient filtration, dust particles, water mist&oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.001mg/m³(21 °C),0.001ppm(w)
FF Dust particles whose diameter more than 0.01 μm, oil vapor &odor can be removed, the maxi. resident content of oil vapor does not exceed 0.003mg/m³(21 °C)?0.003ppm(w)?
AT Dust particles whose diameter more than 1μm can be removed
AAT Dust particles whose diameter more than 0.01μm can be removed

International test and measurement standard ISO12500

>ISO 12500 has made clear a general test and definition method for the compressed air filter manufacturers. The main performance. parameters are the air inlet oil content and particles size distribution of the solid particles.

>ISO12500-1 specifies the test requirements for the filtration performance of oil aerosol in the coalescing filter.

>ISO12500-2 specifies the test requirements of adsorption filters for the removal performance of steam adsorption.

>ISO12500-3 specifies the requirements for removal of particulate matter from solid pullutants.

Product are test with the international advanced testing equipment based on standard ISO12500, Which is equivalent to the standard ISO8573.1-2010 quality standard, and provide filter performance test report.

CONNECTION FACTOR:

Filtration Grade PF AO AF AE FF AT AAT
Size of solid particles(ISO12500-3) 5μm 1μm 0.01μm 0.01μm - 1μm 0.01μm
Filtration performance of solid particles(ISO12500-3) - 99.999+% 99.999+% 99.999+% 99.999+% 99.999+% 99.999+%
Filtration performance of oil (ISO12500-3) 50% 80+% 99.9+5 99.99+% - - -
Residual Oil content (ISO12500-1) 5mg/m3 0.6mg/m3 <0.01mg/m3 <0.001mg/m3 <0.004mg/m3

Flotronics is the top Industrial companies of Industrial Air Filter Elements Manufacturers in Coimbatore. The company offers Air Filter Elements like Carbon Filter, Pre Filter, Activated carbon Filter, etc…

filter elements

Selection guide

What to specify for an accurate quotation

These parameters decide which variant suits your duty. Send what you know — unknown values can be marked for engineering assistance.

Air flow rate
Size the filter to compressor flow at working pressure; undersizing raises pressure drop.
Working pressure
Flow ratings are given at a rated pressure and need a correction factor for other pressures.
Filtration grade
Choose by the particle size and oil carry-over your downstream equipment can tolerate.
Connection size
Port size should match the header pipe to avoid extra losses.
Position in the air treatment train
Fine grades belong after pre-filters and the dryer; tell us what is already installed.
Element change-out
Plan replacement against operating hours and differential pressure.

Typical applications

  • Compressed air filter housings
  • Replacement for existing filters
  • Instrument air
  • Pneumatic tools
  • Painting and packaging
  • Compressor rooms
  • Factory air lines
  • Paint shops

FAQ

Frequently asked questions

Answers to the questions buyers most often ask before requesting a quotation.

How do I know which element grade to order?

Match the grade to your housing and the air quality target. Coarser grades protect finer ones downstream. Tell us the housing make and size and we will check.

What does ISO 12500 cover?

It sets test methods for compressed air filters, including particle and oil aerosol removal. Ask for test details for specific grades.

When should I replace elements?

Replace when differential pressure rises or at the scheduled interval for your duty.

Which element type do I need?

Pre-filter elements catch bulk particles and liquids; fine and carbon elements follow for oil and vapour. Tell us the stage and housing.

Can you match another brand's element?

Send the housing model or sample and we will check the matching element.

How often should elements be changed?

Based on differential pressure and operating hours. Share your duty and we will suggest an interval.

Need replacement filter elements?