An after filter sits downstream of the air dryer and removes fine particles and residual oil mist before air reaches instruments, tools and process equipment.

  • VKB series housings from 1/2" to 4"
  • Listed 0.001 micron after-filter grade
  • Flow table rated at working pressure, with correction factors
  • Low pressure drop and simple installation
  • Used downstream of pre-filter and dryer
Compressed Air After Filters (Fine Filtration)

Application-first selection

Tell us the medium, range and conditions — we match the product type to the duty.

Multi-category sourcing

Instruments, valves, filters, pneumatics and pumps on one enquiry.

Quotation against your specs

Every quote references the parameters you sent, so comparisons are like-for-like.

Engineer-to-engineer support

Ask a technical question before you commit to a model.

Compressed Air Filtration

Range, specifications & options

This page covers the VKB series filter housings, listed in sizes from 1/2" to 4" with a flow table based on rated working pressure. Flotronics supplies after filters alongside pre-filters, dryers and carbon filters so the full treatment train can be matched. Send us your flow, pressure and air quality target and we will recommend a size and prepare a quotation. Confirm specifications against the datasheet for your exact model before ordering.

Need a quote for After Filter?

Send the model or your operating parameters — unsure of a value? Mark it unknown and we will help. Monday to Saturday, 10:00 AM – 5:30 PM.

Product Details:

Flotronics supplies After Filters and to our customers all over India. These filters are available through Flotronics. Our Company was more involved in Offering high range quality products to our customers.

01

ADVANTAGES


1) Easy to handle
2) Low Pressure
3) Warranty:
Filter Housing: 10 Years
Filter Elements: 8000 hours
4) Simple Installation
5) Test and standards details available on request

02

SPECIFICATIONS


Model: VKB series
Size: 1/2″-4″
Max. W.Pressure: 16 Bar
Max.W.Temperature: 90*C
CFM: 20CFM – 2000CFM
AF: 0.001 Micron

03

Technical Specification


The flow rate below is the treatment capacity of compressed air under rated working pressure 7 bar (100psi )
For application in other working pressure, please refer to the correction factors.

Description:

MODEL PIPE SIZE FLOW RATES QTY DIMENSION
L/S M3/min SCFM W D H
VKB010 RC1/2" 16.7 1 35.5 1 96 79 252
VKB020 RC3/4" 25 1.5 53 1 96 79 252
VKB030 RC3/4" 30 1.8 63.6 1 96 79 286
VKB040 RC1" 33.3 2 71 1 96 79 286
VKB060 RC1" 60 3.6 127 1 138 111 357
VKB070 RC1" 83.3 5 177 1 138 111 458
VKB080 RC1-1/2" 125 7.5 265 1 138 111 458
VKB090 RC2" 166.7 10 353.1 1 174 142 558
VKB100 RC2-1/2" 216.7 13 459 1 174 142 558
VKB110 RC2" 283.3 17 600 1 174 142 838
VKB120 RC2-1/2" 316.7 19 671 1 174 142 838
VKB130 RC3" 416.7 25 883 1 220 184 645
VKB140 RC4" 466.7 28 989 1 220 184 645
VKB150 RC3" 683.3 41 1448 1 220 184 902
VKB160 RC4" 800 48 1695 1 220 184 902
Technical Equipments Maxi.operating pressure: 16 bar
Maxi. operating temperature: 80*C
Mini. operating temperature:1.5*C

CONNECTION FACTOR:

Pressure Bar 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Psi 15 29 44 59 73 87 100 116 131 145 160 174 189 203 219 232
Correction factor 0.38 0.53 0.65 0.76 0.85 0.93 1 1.07 1.13 1.19 1.23 1.31 1.36 1.41 1.46 1.51

Net Weight: 1.04KG
Inner Box Size: 31.5*13.0*13.5cm

Selection guide

What to specify for an accurate quotation

These parameters decide which variant suits your duty. Send what you know — unknown values can be marked for engineering assistance.

Air flow rate
Choose the filter by flow at your working pressure, not by pipe size alone.
Working pressure
The flow table is rated at a set pressure; tell us yours so the correction factor can be applied.
Filtration grade
State the required particle and oil carry-over level for your downstream equipment.
Connection size
Match port size to the header to keep pressure drop low.
Position in the train
After filters belong after the dryer and pre-filter; tell us what is installed.
Element change interval
Plan element replacement against operating hours and differential pressure.

Typical applications

  • Instrument air supply
  • Pneumatic tools and automation
  • Packaging and printing
  • Laser cutting machines
  • Spray painting booths

FAQ

Frequently asked questions

Answers to the questions buyers most often ask before requesting a quotation.

Where does an after filter go in a compressed air system?

It goes after the air dryer, and normally after a coalescing pre-filter, to remove the finest remaining particles and oil mist before the air reaches sensitive equipment.

How do I choose the filter size?

Size by air flow at your working pressure. Flow ratings are given at a rated pressure and need correction at other pressures. Send your flow, pressure and pipe size and we will recommend a model.

Does an after filter remove oil vapour?

Fine coalescing filters remove oil mist and aerosols but not vapour. For oil vapour and odour an activated carbon filter is used downstream. We can quote the combination you need.

What do you need to quote an after filter?

Please send air flow, working pressure, pipe size, required air quality and details of existing filters and dryer. We will propose a suitable filter and send a quotation.

Need an after filter for your air line?

Send us the media, size, pressure and temperature, connection and quantity for a quotation, or ask our engineers to help you select the right option.

CallWhatsAppRequest Quote