Compressed Air Filtration
Compressed Air After Filters (Fine Filtration)
An after filter sits downstream of the air dryer and removes fine particles and residual oil mist before air reaches instruments, tools and process equipment.
- VKB series housings from 1/2" to 4"
- Listed 0.001 micron after-filter grade
- Flow table rated at working pressure, with correction factors
- Low pressure drop and simple installation
- Used downstream of pre-filter and dryer

Application-first selection
Tell us the medium, range and conditions — we match the product type to the duty.
Multi-category sourcing
Instruments, valves, filters, pneumatics and pumps on one enquiry.
Quotation against your specs
Every quote references the parameters you sent, so comparisons are like-for-like.
Engineer-to-engineer support
Ask a technical question before you commit to a model.
Compressed Air Filtration
Range, specifications & options
This page covers the VKB series filter housings, listed in sizes from 1/2" to 4" with a flow table based on rated working pressure. Flotronics supplies after filters alongside pre-filters, dryers and carbon filters so the full treatment train can be matched. Send us your flow, pressure and air quality target and we will recommend a size and prepare a quotation. Confirm specifications against the datasheet for your exact model before ordering.
Need a quote for After Filter?
Send the model or your operating parameters — unsure of a value? Mark it unknown and we will help. Monday to Saturday, 10:00 AM – 5:30 PM.
Product Details:
Flotronics supplies After Filters and to our customers all over India. These filters are available through Flotronics. Our Company was more involved in Offering high range quality products to our customers.
ADVANTAGES
1) Easy to handle
2) Low Pressure
3) Warranty:
Filter Housing: 10 Years
Filter Elements: 8000 hours
4) Simple Installation
5) Test and standards details available on request
SPECIFICATIONS
Model: VKB series
Size: 1/2″-4″
Max. W.Pressure: 16 Bar
Max.W.Temperature: 90*C
CFM: 20CFM – 2000CFM
AF: 0.001 Micron
Technical Specification
The flow rate below is the treatment capacity of compressed air under rated working pressure 7 bar (100psi )
For application in other working pressure, please refer to the correction factors.
Description:
| MODEL | PIPE SIZE | FLOW RATES | QTY | DIMENSION | ||||
|---|---|---|---|---|---|---|---|---|
| L/S | M3/min | SCFM | W | D | H | |||
| VKB010 | RC1/2" | 16.7 | 1 | 35.5 | 1 | 96 | 79 | 252 |
| VKB020 | RC3/4" | 25 | 1.5 | 53 | 1 | 96 | 79 | 252 |
| VKB030 | RC3/4" | 30 | 1.8 | 63.6 | 1 | 96 | 79 | 286 |
| VKB040 | RC1" | 33.3 | 2 | 71 | 1 | 96 | 79 | 286 |
| VKB060 | RC1" | 60 | 3.6 | 127 | 1 | 138 | 111 | 357 |
| VKB070 | RC1" | 83.3 | 5 | 177 | 1 | 138 | 111 | 458 |
| VKB080 | RC1-1/2" | 125 | 7.5 | 265 | 1 | 138 | 111 | 458 |
| VKB090 | RC2" | 166.7 | 10 | 353.1 | 1 | 174 | 142 | 558 |
| VKB100 | RC2-1/2" | 216.7 | 13 | 459 | 1 | 174 | 142 | 558 |
| VKB110 | RC2" | 283.3 | 17 | 600 | 1 | 174 | 142 | 838 |
| VKB120 | RC2-1/2" | 316.7 | 19 | 671 | 1 | 174 | 142 | 838 |
| VKB130 | RC3" | 416.7 | 25 | 883 | 1 | 220 | 184 | 645 |
| VKB140 | RC4" | 466.7 | 28 | 989 | 1 | 220 | 184 | 645 |
| VKB150 | RC3" | 683.3 | 41 | 1448 | 1 | 220 | 184 | 902 |
| VKB160 | RC4" | 800 | 48 | 1695 | 1 | 220 | 184 | 902 |
| Technical Equipments | Maxi.operating pressure: 16 bar | |||||||
| Maxi. operating temperature: 80*C | ||||||||
| Mini. operating temperature:1.5*C |
CONNECTION FACTOR:
| Pressure | Bar | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Psi | 15 | 29 | 44 | 59 | 73 | 87 | 100 | 116 | 131 | 145 | 160 | 174 | 189 | 203 | 219 | 232 | |
| Correction factor | 0.38 | 0.53 | 0.65 | 0.76 | 0.85 | 0.93 | 1 | 1.07 | 1.13 | 1.19 | 1.23 | 1.31 | 1.36 | 1.41 | 1.46 | 1.51 |
Net Weight: 1.04KG
Inner Box Size: 31.5*13.0*13.5cm
Selection guide
What to specify for an accurate quotation
These parameters decide which variant suits your duty. Send what you know — unknown values can be marked for engineering assistance.
Typical applications
- Instrument air supply
- Pneumatic tools and automation
- Packaging and printing
- Laser cutting machines
- Spray painting booths
FAQ
Frequently asked questions
Answers to the questions buyers most often ask before requesting a quotation.
Where does an after filter go in a compressed air system?
It goes after the air dryer, and normally after a coalescing pre-filter, to remove the finest remaining particles and oil mist before the air reaches sensitive equipment.
How do I choose the filter size?
Size by air flow at your working pressure. Flow ratings are given at a rated pressure and need correction at other pressures. Send your flow, pressure and pipe size and we will recommend a model.
Does an after filter remove oil vapour?
Fine coalescing filters remove oil mist and aerosols but not vapour. For oil vapour and odour an activated carbon filter is used downstream. We can quote the combination you need.
What do you need to quote an after filter?
Please send air flow, working pressure, pipe size, required air quality and details of existing filters and dryer. We will propose a suitable filter and send a quotation.